OUTDOOR CABLES

FIBRE TO ANTENNA, FTTA SOLUTIONS FOR RADIO BASED STATIONS

Tactical Optical Fibre Cables

Ipsum

Typical Cross section of 2 Fibre

Cable Construction Details

  • 聴Enhance low water peak single mode fibers in full compliance with ITU-T-G.652.D (also available with G657 SM Fibre and OM1 / OM2 / OM3 & OM4 MM Fibre)聴
  • 聴Tight coated fiber with Ny-12/LSZH聴
  • 聴聴Aramid Yarn over tight coated fiber
  • 聴聴LSZH Sheath over Aramid yarn
  • 聴聴Polyester tape wrapping
  • 聴聴Corrugated Steel tape armouring
  • 聴Outer Sheath of UV resistant PE, Black
FIBRE COUNT DIAMETER (mm) Nominal WEIGHT (Kg./Km) Nominal TENSILE STRENGTH (N) BENDING RADIUS (mm) TEMPERATURE RANGE
(IEC 62019-09-15-F1)
Installation Operating Temporary Permanent Installation Operating
2F 8.5 70 350 300 15D 20D -20掳 to +50掳 C -40掳 to +70掳 C

Color Coding - Fibre & Tube

Blue Orange Green Brown Grey White Red Black Yellow Violet Pink Aqua

Special Features

  • 聴Fibre-fed remote radios (RRs) offer significant power savings聴
  • 聴聴Reduces wind and weight load on towers; avoid costly tower upgrades.
  • 聴Reduces installation cost through fewer cables sheaths (70% less) compared to coax.聴
  • 聴聴Reduces installation time through fewer cable sheaths.
  • 聴聴Fast and easy connection and upgrade via tower-top terminal.
  • 聴聴Pre-provision for future equipment additions (spare ports).
  • 聴聴Ruggedized cable with corrugated steel tape armoured providing termite resistance, protection against rodents, birds, squirrels & monkey bite.

Mechanical Characteristics

Repeated Bending (IEC 62019-09-15-E6 30 Cycle, 20 X D, 5 Kg Load, D = Cable D
Torsion Resistance (IEC 62019-09-15-E7) 10 Cycle (卤 180掳) 5 Kg Weight, L= 2 Mtr
Crush Resistance (IEC 62019-09-15-E3) 2000 N (100 X 100 mm) for 600 sec
Impact Resistance (IEC 62019-09-15-E4) Height 500 mm, Weight = 5 Kg, 3 Nos at different points
Kink Resistance (IEC 62019-09-15-E10) 20 x D, D = Cable D

Drum Length

  • 1000/2000 meters 卤 5%