OUTDOOR CABLES

DIELECTRIC RODENT PROTECTED CABLE (2-144 F)

Ipsum

Typical Cross section of 72 Fibre

Cable Construction Details

  • Upto 144 enhance low water peak single mode fibers in full compliance with ITU-T-G.652.D (also available with G655 / G656 / G657 SM Fibre and OM1 / OM2 / OM3 & OM4 MM Fibre)
  • 聴2/4/6/8/12 fibre per tube combinations are available in 6/8/12 element construction
  • 聴Non-metallic and anti-buckling element FRP rod used as Central Strength Member.
  • 聴Loose buffer tubes fully filled Thixotropic Jelly
  • 聴Loose buffer tubes S-Z Stranded
  • 聴Cable core is fully filled with Thixotropic Jelly (also available in dry core design)
  • Cable core is wrapped with Polyester Tape / Water swellable tape
  • 聴UV Stabilized PE inner sheath, Black
  • 聴Glass Yarns used as dielectric armour
  • 聴UV Stabilized PE outer sheath, Black
FIBRE COUNT DIAMETER (mm) Nominal WEIGHT (Kg./Km) Nominal TENSILE STRENGTH (N) BENDING RADIUS (mm) TEMPERATURE RANGE
(IEC 62019-09-15-F1)
Installation Operating Temporary Permanent Installation Operating
UPTO 48F 12.6 135 3000 2000 15D 20D -10掳 to +50掳 C -40掳 to +70掳 C
72F 13.8 160 3000 2000 15D 20D -10掳 to +50掳 C -40掳 to +70掳 C
96F 15.3 195 3000 2000 15D 20D -10掳 to +50掳 C -40掳 to +70掳 C
144F 18.3 270 3000 2000 15D 20D -10掳 to +50掳 C -40掳 to +70掳 C

Special Features

  • 聴Single layer stranded construction
  • 聴Particularly robust cable
  • 聴Flexible buffer tubes provide easy fibre routing inside closure
  • 聴All dielectric armoured

Mechanical Characteristics

Repeated Bending (IEC 62019-09-15-E6) 30 Cycle, r= 20 X D, 5 Kg Load, D = Cable D
Torsion Resistance (IEC 62019-09-15-E7) 10 Cycle (卤 360掳) 5 Kg Weight, L= 2 Mtr
Crush Resistance (IEC 62019-09-15-E3) 2500 N (100 X 100mm) for 600 sec
Impact Resistance (IEC 62019-09-15-E4) Height 500 mm, Weight = 5 Kg, 3 Nos
Kink Resistance (IEC 62019-09-15-E10) 10 x D, D = Cable D
Water Penetration (IEC 62019-09-15-F5B) 1 Mtr Water Head, 3 Meter Cable Sample, 24 Hours